SIGMA BAG TYPE AIR FILTERS

SIGMA BAG TYPE AIR FILTERS

Introduction :These Filters are designed specifically for very high eff. Requirement in paint shop for automobile Industry, It is also designed for pharmaceutical, Chemical Industry, synthetic rayon Industries. These Filters offers low resistance and high dust holding capacity.
The Filter frame are made of metallic sheet and rods with powder coated. The bags media of Filter is Imported glass Fibre media and non woven synthetic fibres. The bag are made with stitching or welding. The bags media are bonded and assembled in such manner in the casing to avoid leakages.

Sr. No. Filter Type EU Class Dust Collection Filter Size No. of Bags Length of Bags Air flow Cmh.
1 F7 EU-7 99% 610X610X25 6 750 3400
2 F7 EU-7 99% 592X592X25 6 750 3400
3 F7 EU-7 99% 592X300X25 4 750 1700
4 F5 EU-5 98% 610X610X25 6 600 3600
5 F5 EU-5 98% 592X592X25 6 600 3600
6 F7 EU-5 98% 592X300X25 4 600 1800
7 G3 EU-3 90% 592X592X25 6 360 3600
8 G3 EU-3 90% 610X610X25 6 360 3600
9 G3 EU-3 90% 610X300X25 4 360 1800

SIGMA POLYFIBRE OR GOASE AIR FILTERS
Goase Air Filters are designed for very high Filtration and dust loading condition. These filter plays an important role of pre filter. These Filters are washable type These Filters are very light in weight. The main application of these filters are in general air conditioning and ventilation system. In Industrial offices, Factories, building centralis air conditioning, cinema theaters. Centralise air conditioning in Five star hotels, etc. The eff. of these Filters is 85% to 90% EU -3 type 20 micron filter.

Sr. No. Size Air Flow Rate(C F M) Cmh.
1 24″X24″X2″ 1700 2840
2 25″X20″X2″ 1450 2420
3 24″X20″X2″ 1400 2340
4 20″X20″X2″ 1100 1840
5 20″X16″X2″ 1100 1840
6 20″X16″X2″ 1000 1670

SIGMA PASS BOX
These units are mostly used in pharmaceutical Industry. There are two types of pass boxes
A) Static pass box
These pass box are installed in between two sterile rooms.
B) Dynamic pass box
These pass box are Installed in between sterile to non sterile room, These Dynamic pass box is a fan Filter unit with prefilters and HEPA filters housed along with a fan and motor. The manufacture of construction of both pass boxes are SS/CRCA powder coated.

SIGMA CLEAN AIR MODULE
The clean air module is a fan filter unit with prefilters and Hepa filters housed along with a fan and motor in a SS/CRCA casing. These units are used either for pressurization or for improving the cleanliness level of the room.

SIGMA FIRE RETARDANT FILTER OR DUAL STAGE FIRE RETARDANT FILTER.

SIGMA FIRE RETARDANT FILTER OR DUAL STAGE FIRE RETARDANT FILTER.

Introduction : Fire retardant filter are designed exclusively For high degree temperature unit i.e.. Hot air units, Hot zone, F.B.D. Units. For pharmaceutical, Research Laboratories, Atomic energy, Ordanance and defence., chemical Industries etc. The temp. Range of Filter is 100°c to 600°cc

Construction: The Filter element is constructed from non woven Fibre glass media.Supported and stitched both side by aluminium, SS. Wire-mesh, and pleated to form deep fold. This exclusive design ensures a large filtrating area in ratio to the face area. This filters having high dust rentention capacity and high flow rate. The Filter units are made in standard size and are interchangeable. The M.O.C. of casing is in ALu, s.s. The bonding material is fire retardant type for bonding the folds are separated by alu / s.s. Separators and also provides Alu / s.s. Protective guards. Fire redartenttype gasket is used for to avoided to leakages.

Operating condition: This Filter can with stand very high degree operating temp. Upto 600° c This filters are washable and
cleanable type.

SIGMA DRY FABRIC PANEL TYPE AIR FILTERS

SIGMA DRY FABRIC PANEL TYPE AIR FILTERS

Applications : Designed specifically for High Efficiency requirements in the nuclear, Pharmaceutical, biological, petrochemical, fertilizer and synthetic fibre industries, computer installation and hospitals.

Constructions: The filter elements is constructed from special pressed non woven synthetic filter fabric stitched on a G. I Wire meon support / Rods and crimped to form deep folds. This exclusive design ensures a large filtration area in ratio to the face area of the filter unit. Result -low differential pressure, high dust rentention capacity and high flow rate. The filter units are made in standard sizes and are interchangeable. The filter casing is
provided with a flanged section for easy fitment on to the filter frame. A felt / neoprene sponge rubber sealing is fixed on to the filter flange. The filter folds are separated by Aluminium spacers to ensure uniform distribution of air flow through the filter media – longer service life. The filter element is sealed in to a mild steel casing duly spray painted and stove enameled to counter rust formation. Aluminium filter casings are also available.

Operating Conditions : The Filter unit can be used under conditions of humidity up to and including 100% RH. Exclusive design ensures large filtration area, maximum filtration efficiency and nominal pressure drop vis-a-vis airflow rate. It is recommended that the filter element is replaced every 12-18 months. Dry Fabric Panel Filters are essential in all industrial installations where a high degree of filtration efficiency and nominal pressure drop commensurate with rated flow is required.

Installation : Filter units may be mounted in multiple banks to cater to large volumes of air flow. The units can be mounted on angle iron frames. Specially designed outlet ducts can be supplied for attaching to the frame work of the filter units for fitment with the existing duct. The filter units are made in standard sizes and are interchangeable.

Application : Designed specifically for High Efficiency requirements in air condition and ventilation, Pharmaceutical, fertilizer and synthetic fibre industries, biological, compressors, electronic industries, research labs, nuclear, petrochemical, film processing industries, Paint finishing plants, and hospitals. And use as pre filter to HEPA filters.